NEW QUESTION # 31
What is a limitation when creating a server profile?

  • A. It is not possible to create shared volumes on demand through a server profile
  • B. Administrator cannot define more than 8 connections within a server profile
  • C. ILO management is limited to the integration with Active Directory or LDAP
  • D. BIOS settings can be changed only when UEFI optimized is selected as boot mode

Answer: C


NEW QUESTION # 32
Your customer plans to deploy ESXi systems to HPE Synergy and HPE ProLiant servers using HPE OneView for VMware vCenter Server.
Which statement about HPE OneView for VMware vCenter Server functionality is true for this environment?

  • A. Individual systems can be added to HPE OneView for VMware vCenter Server through an ILO management processor
  • B. HPE ProLiant servers need an HPE OneView for VMware vCenter Server license for full functionality
  • C. HPE Synergy requires HPE Composer 2 for full functionality of HPE OneView for VMware vCenter Server
  • D. Only systems managed using HPE Oneview can use HPE Oneview for VMware vCenter Server functionalities

Answer: B


NEW QUESTION # 33
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives The customer requested the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- An appropriate number of vSAN Standard licenses for each compute node
- One HPE O3940 Storage Module with 40 SSDs - All required cables and options Which statement about this request is true?

  • A. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
  • B. vSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN
  • C. vSphere licenses should be added, as vSAN licenses do not replace vSphere licenses
  • D. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM

Answer: B


NEW QUESTION # 34
After HPE Superdome Flex deployment and nPar setup, you need to verify health status of HPE Superdome Flex components.
Put the steps on the left into the coned order on the right to perform this task.

Answer:

Explanation:


NEW QUESTION # 35
You need to setup HPE Synergy frames after hardware components are discovered within HPE OneView.
Put the steps to achieve this goal into the coned order in the answer area on the right.

Answer:

Explanation:

1 - Create a logical interconnect group with uplink sets.
2 - Create a logical enciosure.
3 - Create an enciosure group.
4 - Create server profile templates and server profiles.
5 - Define all required networks.


NEW QUESTION # 36
Which statement about an HPE Oneview support dump is true?

  • A. Support dump is a binary file that can be opened only in a dedicated application
  • B. Preview support dump is available only when creating an appliance support dump
  • C. Appliance support dump by default contains a logical enclosure support dump
  • D. Support dump can be created if HPE Virtual Connect modules are installed in the frame

Answer: A


NEW QUESTION # 37
Which HPE Virtual Connect feature allows an administrator to suppress excessive inbound multicast broadcast and destination lookup failure (OLF) packets?

  • A. LLDP tagging
  • B. Storm control
  • C. Loop protection
  • D. Pause flood protection

Answer: B


NEW QUESTION # 38
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use Distributed Switches and DRS cluster You are preparing a proposal with the following components:
- HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
- two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
- an appropriate number of the vSphere Standard licenses for each compute node
- one HPE D3940 Storage Modules with 40 SSDs - all required cables and options Which statement about this proposal is true?

  • A. vSphere Standard licenses should be replaced with Enterprise Pius licenses to enable requested features
  • B. 20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drive.
  • C. 2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup
  • D. One HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50GD/S ILM

Answer: A


NEW QUESTION # 39
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?

  • A. Copy the server profile and assign the clone to the new hardware
  • B. Edit the server profile and change server hardware type
  • C. Migrate the application to a Logical JBOD and connect it to the new server
  • D. Create a new server profile template and apply to the new hardware

Answer: B


NEW QUESTION # 40
After deploying HPE Superdome Flex 280 you need to check Core Analysis Engine (CAE) Log.
Click the appropriate section in the HPE Superdome Flex 280 management interface that will allow you to complete this task.

Answer:

Explanation:


NEW QUESTION # 41
Click the drop-down menu that will allow you to define the location of the master modules within the logical interconnect group.

Answer:

Explanation:


NEW QUESTION # 42
Your customer plans to use HPE OneView for VMware vCenter Server to deploy ESXi systems. They created a server profile template that they want to use in HPE OneView.
Put the steps required to configure HPE OneView for VMware vCenter Server on the left into their correct order on the right.

Answer:

Explanation:

1 - Add vCenter Server to HPE OneView for VMware vCenter Server.
2 - Add HPE OneView credentials to the vCenter Server and create OS Deployment Plan.
3 - Upload HPE-friendly ESXi image.
4 - Deploy new ESXi systems using vCenter Server interface.


NEW QUESTION # 43
Click the option that will allow you to change the ESXI image used In an OS Deployment Plan.

Answer:

Explanation:


NEW QUESTION # 44
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames How will this change impact the customer environment?

  • A. The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
  • B. The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.
  • C. The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
  • D. The customer can add a new logical enclosure to an existing setup once all required licenses are added lo HPE OneView and associated with the new frames.

Answer: B


NEW QUESTION # 45
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure Based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should De performed during the expansion process? (Select two.)

  • A. Move one of the master modules to the appropriate interconnect bay in the second frame.
  • B. Create a new logical enclosure based on both HPE Synergy frames.
  • C. Create a new logical interconnect group and enclosure group for two frames setup
  • D. Re-parent an existing enclosure group to the new logical interconnect group.
  • E. Modify an existing logical interconnect to include second HPE Synergy frame.

Answer: B,E


NEW QUESTION # 46
An HPE Synergy customer needs to prevent a timeout and loss of communication during an external switch firmware upgrade.
Click the parameter that the customer should configure within an uplink set to meet this requirement

Answer:

Explanation:


NEW QUESTION # 47
Click the drop-down menu that will allow you to define the location of the master modules within the logical interconnect group.

Answer:

Explanation:


NEW QUESTION # 48
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?

  • A. Install and configure MPIO on me Windows system
  • B. Disable deduplication for this volume at the array level
  • C. Remove the offline disks using Windows Disk Management
  • D. Remove the offline disks using array management tools

Answer: A


NEW QUESTION # 49
Refer to the exhibit.

Which statement about this logical interconnect group is true?

  • A. Both modules are located in different frames for redundancy
  • B. interconnect modules are installed in interconnect bays 1 and 4
  • C. For an uplink set, ports from different modules can be selected
  • D. An additional license is required to change the enclosure count

Answer: D


NEW QUESTION # 50
What is a restriction of using a RoCE network?

  • A. It does not support Private VLAN and Multicast VLAN.
  • B. it is not supported with HPE Virtual Connect SE 40 GD F8 Module for HPE Synergy.
  • C. It does not support smart link and private network features.
  • D. It is by default configured as an untagged network and cannot be a part of a network set.

Answer: D


NEW QUESTION # 51
Which statement about HPE Apollo 2000 Gen10 Plus platform is true?

  • A. It can support a single processor only and up to 4 per chassis
  • B. It offers servers with AMD EPYC and Intel Xeon Scalable CPUs
  • C. It is equipped with HPE Persistent memory by default
  • D. It is fully managed using HPE OneView including all connections

Answer: A


NEW QUESTION # 52
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter. The customer wants to use them to manage HPE Synergy Gen10 compute modules. HPE ProLiant Gen 10 servers and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?

  • A. HPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers
  • B. To use the required plugins HPE ProLiant Gen10 systems must be managed using HPE OneView
  • C. Both HPE Synergy Gen10 full-height compute module plugins will require a license
  • D. HPE Storage integration Pack for VMware vCenter does not support MSA arrays

Answer: A


NEW QUESTION # 53
Your customer plans to deploy VMware ESXi 7. 0 U2, and they are looking for a hardware platform that will allow them to use up to 16 CPU sockets Which HPE compute system meets the customer requirements?

  • A. HPE ProLiant DL580 Gen10
  • B. HPE Superdome Flex system
  • C. HPE Synergy 480 Gen10 Plus
  • D. HPE ProLiant OL380 Gen 10 Plus

Answer: C


NEW QUESTION # 54
......

Guaranteed Success with HPE0-S60 Dumps: https://www.topexamcollection.com/HPE0-S60-vce-collection.html

Pass HP HPE0-S60 Exam – Experts Are Here To Help You: https://drive.google.com/open?id=1qWY4IJFCINMGqdYANrMUzKyGi9Wpm0My