EMC D-PE-OE-01 Exam Overview:
| Certification Vendor: | Dell Technologies |
|---|---|
| Exam Name: | Dell PowerEdge Operate v2 Exam |
| Exam Number: | D-PE-OE-01 |
| Related Certifications: | Dell PowerEdge Portfolio |
| Available Languages: | English |
| Recommended Training: | Dell Technologies Learning & Certification Hub Dell PowerEdge Server Training |
| Exam Registration: | Pearson VUE Dell Certification Portal Dell Technologies Education Services |
| Sample Questions: | EMC D-PE-OE-01 Sample Questions |
| Exam Way: | Typically delivered via Pearson VUE testing centers or online proctoring (varies by region) |
| Official Syllabus URL: | https://education.dell.com |
EMC D-PE-OE-01 Exam Syllabus Topics:
| Section | Objectives |
|---|---|
| Storage and RAID Configuration | - Storage management and disk troubleshooting - RAID concepts and configuration on PowerEdge systems |
| PowerEdge Server Architecture and Components | - Server hardware components overview (CPU, memory, storage, networking) - PowerEdge system lifecycle concepts |
| Monitoring, Maintenance, and Troubleshooting | - System health monitoring and alerts - Basic troubleshooting of hardware and firmware issues |
| iDRAC and Lifecycle Controller Management | - iDRAC remote management configuration and usage - Lifecycle Controller provisioning and updates |
| System Installation and Initial Configuration | - Initial server setup and deployment workflow - BIOS/UEFI configuration basics |
EMC Dell PowerEdge Operate v2 Sample Questions:
A technician needs to install a PCIe NIC into a production server. Six of the seven PCI slots are already populated.
What does the technician need to verify before installing the PCIe NIC?
- A. Server is connected to 220V power, Slot priority for the PCIe NIC to be installed
- B. Physical slot specifications only
- C. Slot priority for the PCIe NIC to be installed, Physical slot specifications
- D. CPU configuration, Server is connected to 220V power
Correct Answer: C 🗳️
A technician recently installed a supported third-party PCIe expansion card and updated the iDRAC firmware on a server. The server is now experiencing internal temperatures that are higher than normal. A second technician is troubleshooting the server and discovers that the expansion card is hot to the touch.
What should the technician do to resolve this issue?
- A. Replace the fans one at a time until the faulty fan is identified.
- B. Reseat all the fans.
- C. Adjust the Multi Vector Cooling values.
- D. Adjust the power settings.
Correct Answer: C 🗳️
SIMULATION
A system administrator is asked to create an iDRAC shared management port using LOM2 and create a failover network using LOM3.
Use the simulator to accomplish this task.
Correct Answer:
Answer in Explanation
Explanation:
To configure an iDRAC shared management port with LOM2 and set up a failover network using LOM3 in the iDRAC interface, follow these steps:
Step-by-Step Guide:
Access iDRAC Network Settings:
In the iDRAC interface, navigate to the iDRAC Settings tab in the top menu bar. Select Network from the dropdown options to access network configuration settings. Configure the Shared Management Port:
In the Network settings, locate the section for Network Interface or LAN Interface Configuration. Change the NIC Selection to Shared. This will enable the use of a LAN on Motherboard (LOM) port for iDRAC management.
Select LOM2 for the Shared Management Port:
Once you've selected Shared, additional options should appear for selecting the specific port. Choose LOM2 as the Shared Management Port. This configures iDRAC to use LOM2 for its primary network connection.
Enable Failover and Select LOM3:
Look for the Failover settings within the same Network Interface configuration.
Enable Failover and select LOM3 as the failover network port. This configuration allows iDRAC to switch to LOM3 automatically if there is an issue with the connection on LOM2.
Save and Apply Settings:
Once you have configured the shared management port and failover settings, click Apply or Save to confirm the configuration.
The iDRAC interface may briefly refresh, and you should receive a confirmation that the settings have been applied successfully.
Verify Configuration:
After the settings are saved, you can verify that LOM2 is listed as the shared management port and that LOM3 is set as the failover port under Network settings.
By following these steps in the simulator, you should be able to configure iDRAC to use LOM2 for the shared management port and set up a failover network with LOM3. Make sure to save your changes to apply the configuration.
Which configuration settings are installed when using Easy Restore?
- A. Asset tag, passwords, and RAID
- B. BIOS, iDRAC, and NIC
- C. IDRAC, BOSS, and partitions
- D. Virtual console, network, and SCP
Correct Answer: B 🗳️
Explanation: Only visible for TopExamCollection members. You can sign-up / login (it's free).
Your company is decommissioning a PowerEdge 16G server to a 17G server. All the disks in the 16G server are SEDs. Your security team requires that the server is securely retired. Which feature can be used to comply with the security requirement?
- A. Enable Lockdown Mode in iDRAC
- B. Use LifeCycle Controller ISE feature
- C. Enable Secure Boot in BIOS
- D. Use SCV application feature
Correct Answer: B 🗳️
Explanation: Only visible for TopExamCollection members. You can sign-up / login (it's free).

We're so confident of our products that we provide no hassle product exchange.