BICSI DCDC-003.1 Exam Overview:
| Certification Vendor: | BICSI |
|---|---|
| Exam Name: | BICSI Data Center Design Consultant (DCDC) |
| Exam Number: | DCDC-003.1 |
| Real Exam Qty: | 100 |
| Exam Format: | Computer-Based Testing (CBT), Multiple Choice |
| Certificate Validity Period: | 3 years |
| Exam Duration: | 120 minutes |
| Available Languages: | English |
| Passing Score: | Scaled score determined by BICSI |
| Exam Price: | $525 USD |
| Related Certifications: | BICSI Data Center Design Consultant (DCDC) |
| Sample Questions: | BICSI DCDC-003.1 Sample Questions |
| Exam Way: | Computer-based exam delivered through Pearson VUE testing centers and authorized online testing options. |
| Pre Condition: | Minimum two years of approved and verifiable experience in data center design and/or construction within the last six years. |
| Official Syllabus URL: | https://www.bicsi.org/education-certification/certification/dcdc |
BICSI DCDC-003.1 Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Security Assessment | 5% | - Risk Management
|
| Systems | 30% | - Fire Protection
|
| Data Center Operations and Maintenance Assessment | 10% | - Operational Readiness
|
| Information Technology, Ancillary Systems and Communications Connectivity | 20% | - Structured Cabling
|
| Concept Planning and Analysis | 25% | - Capacity Planning
|
| Construction Administration and Commissioning | 10% | - Commissioning
|
BICSI Data Center Design Consultant - DCDC Sample Questions:
What is the formula for reliability of components in parallel?
- A. R = 1 - ([1-RA1) * (1-RA2)]
- B. R = RA1 - RA2
- C. R = RA1 + RA2
- D. R = RA1 / RA2
Correct Answer: A 🗳️
What is the Fourth Preference Regarding Utility Service?
- A. At least two circuits from one substation fed via alternative power grid
- B. At least four circuits each from different distribution stations but fed via common feeders
- C. One circuit from one substation, separate paths
- D. Two balanced feeds with different voltages derived from a single distribution station
Correct Answer: C 🗳️
What type of slope is considered too extreme for a data center site?
- A. 15%
- B. 10%
- C. 20%
- D. 5%
Correct Answer: A 🗳️
Apart from Power usage effectiveness or P U E, and Data center infrastructure Efficiency Or D C i E, what other standardized measurements are there for data center efficiency?
- A. None of The Above.
- B. All of the above
- C. Return temperature index.
- D. Energy efficiency Ratio.
Correct Answer: B 🗳️
What is the formula to find the maximum allowable cable depth in a non-solid bottom cable tray?
- A. H = 200/1 + (L * 0.0007)
- B. H = 50/1 + (L * 0.0007)
- C. H = 150/1 + (L * 0.0007)
- D. H = 100/1 + (L * 0.0007)
Correct Answer: C 🗳️